64 • Questions? Call or Text +1-801-658-0015
SUNSTONE CDDP-A USERS GUIDE
Index Holding Register Length Minimum Maximum Note
19
Energy Pulse 2
2 0x00000064
0x00030D40
(200000),
0x00061A80
(400000),
0x000927C0
(600000),
0x00124F80
(1200000)
mWs
21
Time Between Pulses
1 0x0001
0x0064
ms
22
Pre Weld Delay
1 0x0001
0x2710
ms
23
Weld Head Control Type
1 See Table See Table
24
Welds Per Second
1 0x0032
0x03E8
Welds per hecto-
second
25
Alarm Temperature Value
1 0x0000
0x0064
C
26
Alarm Comparator Value
1 0x0001
0x0019
27
Alarm Weld Counter Value
1 0x0001
0x4E20
28
Warning Temperature Value
1 0x0000
0x0064
C
29
Warning Comparator Value
1 0x0001
0x0019
30
Warning Weld Counter Value
1 0x0001
0x4E20
31
PLC Pin 3 - Assignment
1 See Table See Table PLC Input
32
PLC Pin 4 - Assignment
1 See Table See Table PLC Input
33
PLC Pin 7 - Assignment
1 See Table See Table PLC Output
34
PLC Pin 8 - Assignment
1 See Table See Table PLC Output
35
Current Remote Schedule Selection
1 0x0000
0x007F
When no selection
is wanted, set to
0x00FF
HOLDING REGISTERS: REMOTE SCHEDULE SELECT MODES
Remote Schedule Select Mode Value
Disabled 0x0000
Basic 0x0001
Ethernet 0x0002