EasyManua.ls Logo

SUNSTONE CDDP-A - Weld Head Control Types; PLC Output Pin Assignments; PLC Input Pin Assignments

SUNSTONE CDDP-A
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Questions? Call or Text +1-801-658-0015 • 65
e Micro Welder Experts
HOLDING REGISTERS: WELD HEAD CONTROL TYPES
Weld Head Control Type Value
Fully Automatic 0x0000
Automatic with Timing 0x0001
Automatic with Trigger 0x0002
HOLDING REGISTERS: PLC OUTPUT PIN ASSIGNMENTS
PLC Output Pin Assignment Value
Unassigned
0x0000
Weld Ready
0x0001
Weld Good
0x0002
Weld Not Good
0x0003
Emergency Stop
0x0004
Alarm - Any
0x0005
Alarm - Temperature
0x0006
Alarm - Comparator Failures in a Row
0x0007
Alarm - Electrode Stuck
0x0008
Alarm - Weld Counter Preset Limit
0x0009
Alarm - Remote Schedule Selection Invalid
0x000A
Alarm - Part Check Failed
0x000B
Alarm - Trigger in no Weld State
0x000C
Alarm - Wrong Trigger Detected
0x000D
Warning - Any
0x000E
Warning - Temperature
0x000F
Warning - Comparator Failures in a Row
0x0010
Warning - Weld Counter Preset Limit
0x0011
HOLDING REGISTERS: PLC INPUT PIN ASSIGNMENTS
PLC Output Pin Assignment Value
Unassigned
0x0000
Primary Trigger
0x0001
Secondary Trigger
0x0002
Reset Weld Count
0x0003
Lock Out
0x0004
Remote Schedule Select
0x0005

Table of Contents