ELECTRICAL SYSTEM 17-3
Measure the ignition system peak voltage in the following proce-
dure:
Connect the multi circuit tester with the peak volt adaptor as
follows. (See table below.)
Measure the highest peak voltage by depressing the kick
starter lever more than 3 times forcefully.
" Tester knob indication: Voltage (#
##
#)
$ 09900-25008: Multi circuit tester
Connect the magneto lead wire coupler and disconnect the
ignition coil lead wire coupler
2.
Connect the multi circuit tester with the peak volt adaptor
between Black/White lead wire and White/Blue lead wire.
Measure the highest peak voltage by depressing the kick
starter lever more than 3 times forcefully.
NOTE:
Be sure to connect the Red probe to the Black/White lead wire
and the Black probe to the White/Blue lead wire.
Red/White – Black/Red 25 V and more
Green – Red 2 V and more
R/W
G
R
B/R
Black/White – White/Blue 200 V and more
B/WW/Bl