EasyManua.ls Logo

Suzuki Vinson LT-A500F - Page 284

Suzuki Vinson LT-A500F
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ELECTRICAL
SYSTEM
8-29
Make
sure the air bubbles
©
rise to the top
of
each electro-
lyte
container and leave the electrolyte container in this posi-
tion
for more than
20
minutes.
NOTE:
If air bubbles do not rise from any one of the filler ports, tap the
bottom of the electrolyte container two or three times.
Never
remove the electrolyte container from the battery while
there is still electrolyte in the container.
After the electrolyte container is completely empty, remove
it
from the battery and wait about 20 minutes.
Insert the caps
©
firmly into the
filler
holes, so that the top of
the
caps
do
not protrude
above
the upper surface
of
the top
cover
of
the battery.
A CAUTION
The charging system for an MF
battery
is
different
from
that
of a conventional
battery.
Only use the
specified MF
battery.
Do not remove the caps once
they
are installed in
the
battery.
Measure
the battery voltage using the multi circuit tester.
If
the
battery
voltage
is
lower than
the
specified value, charge
the
battery
with
a
battery charger.
IT55LI
09900-25008:
Multi
circuit tester set
Battery voltage
Standard:
12.5-12.6
V (DC)
NOTE:
Initial
charging for a new battery is recommended if two years
have
elapsed since the date of manufacture.
(V)
13
12
11
10
(at
25°C)
t—
2
4 6
Time
8 10
(Minutes)

Table of Contents