WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-7
Keyless entry system circuit check
Terminal Wire Circuit Specification Condition
G02-7 GRN/YEL
Hazard waning signal circuit
(right side)
Figure “A”
Push “LOCK” button on transmitter
once.
Figure “B”
Push “UNLOCKI” button on transmit-
ter once.
Figure “C”
Push “LOCK” button on transmitter
twice within 3 seconds.
G02-8 GRN/RED
Hazard waning signal circuit
(left side)
Figure “A”
Push “LOCK” button on transmitter
once.
Figure “B”
Push “UNLOCK” button on transmit-
ter once.
Figure “C”
Push “LOCK” button on transmitter
twice within 3 seconds.
G02-15 BRN/RED
Door switch & interior light
circuit
Figure “D”
Fulfill the following conditions.
• All door is close.
• Interior light switch is middle posi-
tion.
• 20 seconds after pushing
“UNLOCK” button on transmitter
once
[A] : Figure “A”
[B] : Figure “B”
[C] : Figure “C”
[D] : Figure “D”
[A] [B] [C] [D]
12V
0V
12V
0V
12V
0V
12V
0V
1s/div 1s/div 1s/div 2ms/div