technical reference
SYNRAD FH Series Flyer Operator’s Manual Version 3.4
155
Downloading a custom test mark le
1
Under Tools, click Custom Test Mark… and when the Test Mark Control dialog box opens, verify
that the correct Test Mark Mode options are selected.
Note: The default Test Mark Mode is Manual. To enable Auto Test Mark Mode you must select the Auto
option each time the Test Mark Control dialog box opens.
2
Click OK to download the currently active WinMark le to Flyer memory.
3
After le transfer is complete, a dialog box conrms a successful download.
FH Flyer memory can contain only one custom test mark at a time, but a new mark le can be downloaded
at any time. A copy of the factory installed test pattern (FactoryTestMark1.mkh) is provided in the Program
Files\WinMark folder so that the default test mark le can be reloaded into memory as required for lens
testing or mark centering.
Custom test mark I/O
Inputs
FH Flyer can read inputs (IN0–IN7) during a custom test mark. This input capability is available when
using any Wait Digital command on the Drawing’s Automation tab or when using MatchDigitalState and
WaitDigitalState Event Builder commands during On Before Mark Session, On Before Mark Piece, On
After Mark Piece, and On After Mark Session stages of the automation loop. The On Abort Session
event is not a valid custom test mark state.
Custom test mark feature
In WinMark Pro’s automation loop, On Before Mark Session and On After Mark Session events run
only once before/after a marking session while On Before Mark Piece and On After Mark Piece events
run before/after each individual piece. In a custom test mark application however, each individual mark is
considered a mark session, meaning that On Before Mark Session / On After Mark Session events are
run for each piece that is marked.