220
Troubleshooting
Line speed is set too fast.
Lower line speed.
The mark is being made too slowly for the required line speed.
Open the mark le in WinMark Pro and do the following: (1) shorten mark time by changing fonts,
decreasing font size, or reducing line spacing; (2) simplify or eliminate graphic objects in the mark; or (3)
reduce graphic object size or resolution.
Symptom:
Tracking marks are skewed or distorted.
Possible Causes:
The Encoder Resolution value is set improperly.
Load and mark the appropriate linestackxxx.mkh le (located in the WinMark software folder). Refer to
Tracking hardware - position encoder in the Tracking chapter for instructions on how to ne-tune encoder
resolution settings.
The Product Line Speed value is set improperly.
If Encoderless Tracking is specied, check that Product Line Speed (on the “Device tab under Tools /
General Settings…) is equal to conveyor or part velocity. Adjust Product Line Speed as required to ne-
tune tracking to actual part motion.
Line speed is set too fast.
Lower line speed.
The actual part motion vector is dierent from the value entered as the Motion Vector.
Check that actual part motion under the marking head equals the entered Motion Vector (on the “Device
tab under Tools / General Settings…). WinMark Pro v6 and FH Flyer support Motion Vector values in
0.01° increments.
Automation I/O
Symptom:
FH Flyer is not responding to automation inputs or the automation controller is not “seeing Flyer
outputs.
Possible Causes:
I/O voltage levels are incorrect.