EasyManua.ls Logo

T-Drill S-80 - Stopping the Machine; Emergency Stopping; Normal Stopping of the S-80 Unit

Default Icon
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COLLARING MACHINE
47
S-80
6.3. STOPPING THE MACHINE
6.3.1. EMERGENCY STOPPING
In case of danger, stop the machines by pressing the EMERGENCY STOP push buon
completely down. This immediately interrupts all funcons of the S-80 unit.
¨NOT!¨ 

When the light curtain has been interrupted during the work cycle, the HOMING of all
movements has to be done in Manual screen:
Aer homing the last workpiece is removed, and a new workpiece can be placed to the
clamps and a new work cycle can be started.
When the light curtain has been interrupted during the tool change or the EMERGENCY
STOP push buon has been pushed, all movements (axis and cylinders) have to be driven
to correct posions on Manual screen.
For a controlled interrupt of the safety curtain, see 6.1.3. Control panel instrucons: Use
the “Enter the safety area request buon”.

1. Wait unl the unit has nished the automac work cycle.
2. Disconnect the main power from the main power switch (O) on the electric cabinet.
3. Close the air supply main valve on the pressure regulator.

Table of Contents