INSTRUCTION MANUAL
58
1
2
3
4
5
6
7
8
9
10
1. Tube holder, 2. Locking lever for posioner, 3. Posioner (pin to hole), 4. Gas spring, 5
Li / lower locking knob, 6. Posioning plate (2 sets of holes), 7. Angle posioning plate,
8. Tube clamp operang lever, 9. Tube clamp, 10. Angle posioning knob.
To use the MFT:
Open clamp (9) by the lever (8).
Place the tube to Tube holder (1) and to the clamp (9), close the clamp.
Adjust height for the collaring of the le end of the tube: Pull knob (5) and adjust height,
the gas spring (4) will ease liing.
Adjust correct posioning plate: open locking lever (2) and pull knob (3) to adjust height.
Lock the posioner. To slide the posioner to next posioning point (hole), pull the knob
(3) and push the device to point.
Adjust correct angle: Pull knob 10 and turn the angle plate to desired angle (posioning
holes are for rotaon of 0, 5 or 50 degrees).