INSTRUCTION MANUAL
82
Problem Cause Remedy
Tap “Cycle start” on
control panel:
ALARM: Collaring
process cannot be
started
Air pressure o
Check air pressure line, switch
on air pressure to the collaring
unit: press Reset on control
panel
Is the collaring tool fastened
properly?
Liing cylinder not up (20-B1.1)
Check the cylinder posions and
move to correct posion using
MANUAL
Locking cylinder not on the side
(20-B2.0)
Work piece sensor is acvated (10-
B4)
Check work piece sensor, there
should be nothing pushing
sensor.
The S1 and S2 axis are not in home
/ start posion (+/- 2 deg)
Do homing.



The name of the company
Your own name and posion
Telephone number
Fax number
e-mail –address

The serial number of the machine
Type code
The reading of the piece counter
Short descripon of the appeared problem.