1. Double-tap the T
rigger badge on the Settings bar.
2. Set the Trigger Type to Video.
Settings panel (Video Trigger configuration menu) fields and controls
Field or control Description
Trigger Type Set to V
ideo.
Source
Lists the source channel or waveform to use to trigger.
Format Set the video format from the drop-down list.
Trigger On Set to trigger on lines or fields from the drop-down list.
Line Number Set the line number to trigger on. This control is only available when Trigger On is set to Line Number.
Polarity Sets the video polarity. (Normal or Inverted).
Scan Method Set the scan method to Progressive or Interlaced.
Line Period Set the line period when the format is set to Bilevel Custom or Trilevel Custom.
Sync Interval Set the sync interval when the format is set to Bilevel Custom or Trilevel Custom.
Mode & Holdoff
Trigger Mode determines how the instrument behaves in the absence or presence of a trigger event.
Holdoff sets the amount of time the oscilloscope waits after a trigger event before detecting and
triggering on the next trigger event.
For additional information on Trigger Mode, Holdoff, forcing a trigger, and the Trigger Frequency
Counter see Mode and Holdoff panel on page 226.
Act On Trigger
Set the actions the instrument takes when a trigger event occurs.
For additional information on the Act On Trigger panel see Act On Trigger configuration
menu on page 227.
Trigger types
Use the following links to see more information on specific trigger types.
Edge T
rigger menu
Pulse Width Trigger menu
Timeout Trigger menu
Runt Trigger menu
Logic Trigger menu
Setup & Hold Trigger menu
Rise/Fall Time Trigger menu
Video Trigger menu
Bus Trigger menu
Sequence Trigger menu
Mode and Holdoff panel
Use the mode and holdoff panel controls to stabilize triggering.
To open the Pulse Width trigger configuration menu:
1. Double-tap the Trigger badge on the Settings bar.
Menus and dialog boxes
3 Series Mixed Domain Oscilloscope Printable Help 226

Table of Contents

Other manuals for Tektronix MDO34

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MDO34 and is the answer not in the manual?

Tektronix MDO34 Specifications

General IconGeneral
Analog Channels4
Sample Rate2.5 GS/s
Record Length10 Mpoints
Mixed Domain AnalysisYes
Waveform Capture Rate>280, 000 wfms/s
Spectrum Analyzer Frequency Range9 kHz to 3 GHz
Vertical Resolution8 bits
Input CouplingAC, DC, GND
Operating Temperature0°C to +50°C
Digital Channels16
ConnectivityUSB, LAN, HDMI
Arbitrary Function Generator50 MHz
Trigger TypesEdge, Pulse Width, Runt, Logic, Setup/Hold, Rise/Fall Time, Video
Input Impedance1 MΩ
Maximum Input Voltage300 Vrms
Dimensions140 mm
Weight4.5 kg
Bandwidth100 MHz, 200 MHz, 350 MHz, 500 MHz
Display10.1-inch capacitive touch HD display
Voltmeter4-digit

Related product manuals