EasyManuals Logo

Tektronix MDO34 User Manual

Tektronix MDO34
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #234 background imageLoading...
Page #234 background image
Field or control Description
Spectrogram
Toggles the spectrogram traces on or off. The spectrogram display is useful for monitoring slowly-
changing RF phenomena. The x-axis represents frequency
, just like the typical spectrum display. The
y-axis represents time. Color indicates amplitude.
Spectrogram slices are generated by taking each spectrum and flipping it on its edge so that it is one
pixel row tall, and then assigning colors to each pixel based on the amplitude at that frequency with
the cold colors of blue and green representing low amplitude, and the hotter colors of yellow and red
indicating higher amplitude. Each new acquisition adds another slice at the bottom of the spectrogram,
and the history moves up one row.
Menus and dialog boxes
3 Series Mixed Domain Oscilloscope Printable Help 234

Table of Contents

Other manuals for Tektronix MDO34

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MDO34 and is the answer not in the manual?

Tektronix MDO34 Specifications

General IconGeneral
Analog Channels4
Sample Rate2.5 GS/s
Record Length10 Mpoints
Mixed Domain AnalysisYes
Waveform Capture Rate>280, 000 wfms/s
Spectrum Analyzer Frequency Range9 kHz to 3 GHz
Vertical Resolution8 bits
Input CouplingAC, DC, GND
Operating Temperature0°C to +50°C
Digital Channels16
ConnectivityUSB, LAN, HDMI
Arbitrary Function Generator50 MHz
Trigger TypesEdge, Pulse Width, Runt, Logic, Setup/Hold, Rise/Fall Time, Video
Input Impedance1 MΩ
Maximum Input Voltage300 Vrms
Dimensions140 mm
Weight4.5 kg
Bandwidth100 MHz, 200 MHz, 350 MHz, 500 MHz
Display10.1-inch capacitive touch HD display
Voltmeter4-digit