Application Examples
6. Push the Ch1 sid
e menu. The pop-up menu of measurement types appears
to the left. .
7. Turn the Multi
purpose knob to highlight Peak-Peak.
8. Push the Multipurpose knobtoselectPeak-Peak. A check should appear
next to the m
enu item and the peak-to-peak for channel 2 should appear
towards the bottom of the display.
9. Read the dis
played peak-to-peak amplitudes for both channels.
10. To ca lculate the amplier voltage gain, use these equations:
VoltageGain = output amplitude/input amplitude
VoltageGain (dB) = 20 × log
10
(VoltageGain)