TELOS TWOX12 USERS MANUAL
SPECIFICATIONS
CHAPTER 6 164
Frequency Response (± .5dB, 50 to 20kHz; swept sine procedure)
Measured from analog Input to output with unit in loopback mode.
Noise Input (-93 dBFS, A weighted)
Measured analog in to AES out in loopback mode.
Noise Output (-80 dBFS, A weighted)
Measured AES in to analog out in loopback mode.
THD+N - Input (< 0.06% typical)
Measured at 0 dBu @ 1 kHz analog in to AES out in loopback mode.
Digital-to-analog converter resolution; 16 bits
Transhybrid Loss
POTS Interface (typ)
ISDN Interface (typ)
AES/EBU Digital Inputs/Outputs
Sample rates supported; 32, 44.1, and 48kHz.
Rate conversion; Input and output independently selectable.
Input clock; AES input or ISDN network clock.
Input Level; Adjustable -27 to 12 dBfs
Output Level; Adjustable 27 to 12dBfs
Control Ports
RS-232; 9 Pin D-sub connector
DCE connector supports asynchronous data, 8 bits, no parity, 2 stop bits, 2400-38,400 bits
per second.
Ethernet; 10Base-T
General purpose Input/Output
15 pin D-Sub connector with 5 status outputs and 4 control inputs.