TELOS TWOX12 USER’S MANUAL
GETTING UP & GOING – SYSTEM CONFIGURATION
CHAPTER 3 63
w
IMPORTANT!
Users in the USA & Canada should see READY status for each line whenever the
system is idle. On certain ETS- 300 ISDN lines the lines may go from READY to
DEACTIVATED after an idle period. This is no cause for alarm and you can proceed
with the following steps.
Once you see “READY ” for each channel on the appropriate Slot - Status screens we can
proceed to make a call and verify that the ISDN lines are, in fact, working. We will start out
with the simplest case, a call from your “line 1” to your “line 2”as follows:
• Confirm that the Desktop Director™ you will be using has power and says “Talent” at
the top of the screen. If it says “Producer” follow the directions in section 4.4.2 to
change this Director to “Talent” mode.
• First pick up the handset and push each line button in the left row listening for dial
tone. If this does not happen see section 8 for information on troubleshooting your
problem.
• Next, pick up the handset and press the left Line 1 button to select that line for dialing.
You should now hear dial tone on the handset.
• Enter the phone number for line 2 using the numeric keypad.
• You should now hear a ringing sound and see the ringing Status Symbol (an
expanding square) on Line 2. Push the right Line 2 button to answer this call. The
→ Icon should appear for line one.
• Drop this test call by pressing the right Drop button
.
• If this happens, your “lines” 1 and 2 are working (if you are using ISDN BRI circuits
you have now tested the first BRI). If this does not happen see section 8 for information
on troubleshooting your problem.
• Now repeat this test by calling from “Line 2” to “Line 3”, “Line 3” to “Line 4” etc
until all lines have been tested.
• If you do not plan on proceeding to the next section and setting your levels now, be
sure to push the Drop button
after the final call.
h
HOT TIP!
Many phone lines have per- minute usage charges. Don’t forget to drop the call once
your testing and configuration are complete.