Premier Elite 24,24-W, 48,48-W, 88, 168 & 640 Installation Manual UDL & Digi Options
INS176-9 101
No Zone Type Event Reporting Group Contact ID SIA
11 Auxiliary Alarm Alarm Tamper 150 UA
Alarm Restore Restore 150 UH
Omit Omit/Reinstate 572 UB
Reinstate Omit/Reinstate 572 UU
12 24Hr Tamper Alarm Alarm Tamper 137 TA
Alarm Restore Restore 137 TR
Omit Omit/Reinstate 572 TB
Reinstate Omit/Reinstate 572 TU
13 Exit Terminator Alarm Open/Close --- --
Alarm Restore Open/Close --- --
Omit Omit/Reinstate 570 UB
Reinstate Omit/Reinstate 570 UU
14 Keyswitch - Momentary Alarm Open/Close 409 OP
Alarm Restore Open/Close 409 CL
Omit Omit/Reinstate 570 UB
Reinstate Omit/Reinstate 570 UU
15 Keyswitch - Latching Alarm Open/Close 409 OP
Alarm Restore Open/Close 409 CL
Omit Omit/Reinstate 570 UB
Reinstate Omit/Reinstate 570 UU
16 Security Key Alarm Open/Close 421 DK
Alarm Restore Open/Close 421 DG
Omit Omit/Reinstate 570 UB
Reinstate Omit/Reinstate 570 UU
17 Omit Key Alarm Omit/Reinstate --- --
Alarm Restore Omit/Reinstate --- --
Omit Omit/Reinstate 570 UB
Reinstate Omit/Reinstate 570 UU
18 Custom Alarm Omit/Reinstate --- --
Alarm Restore Omit/Reinstate --- --
Omit Omit/Reinstate 570 UB
Reinstate Omit/Reinstate 570 UU
19 Confirmed PA Audible Alarm Priority Alarm 123 PA
Alarm Restore Restore 123 PH
Omit Omit/Reinstate 573 PB
Reinstate Omit/Reinstate 573 PU
20 Confirmed PA Silent Alarm Priority Alarm 122 HA
Alarm Restore Restore 122 HH
Omit Omit/Reinstate 573 HB
Reinstate Omit/Reinstate 573 HU