EasyManua.ls Logo

Texecom Premier Elite 24

Texecom Premier Elite 24
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UDL & Digi Options Premier Elite 24,24-W, 48,48-W, 88, 168 & 640 Installation Manual
102 INS176-9
Non-Zone Event Types
The default Non-Zone Event codes are as follows:
No Type Event Reporting Group Contact ID SIA ID
22 Keypad Medical Alarm Priority Alarm 100 MA Keypad No *
Restore Restore 100 MH Keypad No *
23 Keypad Fire Alarm Priority Alarm 115 FA Keypad No *
Restore Restore 115 FH Keypad No *
24 Keypad Audible PA Alarm Priority Alarm 120 PA Keypad No *
Restore Restore 120 PH Keypad No *
25 Keypad Silent PA Alarm Priority Alarm 122 PA Keypad No *
Restore Restore 122 PH Keypad No *
26 Duress Code Alarm Alarm Priority Alarm 121 HA User No
Restore Restore - 122 HH User No
27 Alarm Active Alarm Not Reported - - -
Restore Not Reported - - -
28 Bell Active Alarm Not Reported - - -
Restore Not Reported - - -
29 Zones Locked Out Alarm Alarm 130 BA Zone No
Restore Not Reported - - -
30 Verified Cross Zone Alarm Alarm Alarm 130 BV 00
Restore Not Reported - - -
31 User Code Alarm Not Reported - - User No
Restore Not Reported - - -
32 Exit Started Alarm Not Reported - - Keypad No
Restore Not Reported - - -
33 Exit Error (Arming Failed) Alarm Open/Close 457 EE 00
Restore Not Reported - - -
34 Entry Started Alarm Not Reported - - -
Restore Not Reported - - -
35 Area Arm Suite Alarm Open/Close - - Suite No 1 - 8
Restore Open/Close - - -
36 Armed with Line Fault Alarm Not Reported - - User No
Restore Not Reported - - -
37 Open/Close (Full Arm) Alarm Open/Close 401 OP User No
Restore Open/Close 401 CL User No
38 Open/Close (Part Arm) Alarm Open/Close 401 OP User No
Restore Open/Close 401 CL User No
39 Auto Open/Close Alarm Open/Close 403 OA 00
Restore Open/Close 403 CA 00
40 Auto Arm Deferred Alarm Open/Close 405 CE User No
Restore Open/Close - - -
41 Open After Alarm (Alarm Abort) Alarm Open/Close 406 OR 00
Restore Not Reported - - -
42 Remote Open/Close Alarm Open/Close 407 OP 00
Restore Open/Close 407 CL 00
43 Quick Arm Alarm Not Reported - - -
Restore Open/Close 408 CL Keypad No *
44 Recent Closing Alarm Open/Close 459 CR 00
Restore Not Reported - - -
45 Reset After Alarm Alarm Restore - - Reset ID ****
Restore Not Reported - - -
46 Power Output Fault Alarm Maintenance 300 YP Device ID **
Restore Restore 300 YQ Device ID **
47 AC Fail Alarm Maintenance 301 AT 00
Restore Restore 301 AR 00

Table of Contents