Chapter 6 Additive Control
220
Firmware Version 3/4.31.37
8. Record the volume collected in the beaker.
9. Press EXIT.
10. A ‘Please Wait’ message displays briefly, then the following screen displays:
11. To enter the collected beaker volume in thousandths of a gallons, press 1.
12. To enter the collected beaker volume in CCs, press 2 (as shown below).
PRE #1 ADTV #1 (Adtv 001 ) CALIBRATE
Press Next Key to Inject Now!
Injection: 5
Meter Pulses: 261
Delivered Volume: 0.100( 379cc)
Exit
PRE #1 ADTV #1 (Adtv 001 ) CALIBRATE
Delivered Vol: 0.100( 379cc)
[1]Beaker Vol: 0.000000
[2]Beaker Vol CCs: 0.000
Meter Pulses: 261
Additive Mtr K-Factr: 2600
Exit