58
[Counting condition] The number of times the print head moves up and down
with the solenoid for ribbon save is counted. (A set of up and down is counted
as one.)
The head up/down count is saved every 4 head up/down operations.
[Description] Ribbon motor drive time
[Counting condition] Counted when the ribbon motor is driven while media feed
or printing. (Reverse feed is also counted.)
When the power is turned off, drive time of 10 seconds or less is rounded
down when backed up.
[Description] Head-up solenoid drive time
[Counting condition] Counted when the ribbon save operation is performed.
When the power is turned off, drive time of 10 seconds or less is rounded
down when backed up.
[Description] The number of times an RS-232C hardware error occurred
[Counting condition] Counted when a parity error, overrun error or framing
error occurs.
[Description] The number of times a system error occurred
[Counting condition] Counted when a system error occurs.
[Description] The number of times a momentary power interruption occurred
[Counting condition] Counted when a momentary power interruption occurs.
<< ADJUST >>
Feed amount fine adjustment
Cut position (or strip position) fine adjustment
Reverse feed amount fine adjustment
Print density fine adjustment
(Thermal transfer print mode)
B-EX6T1/T3: -20 to +20 step
B-EX4T1: -10 to +10 step
Print density fine adjustment
(Direct thermal print mode)
B-EX6T1/T3: -20 to +20 step
B-EX4T1: -10 to +10 step
Ribbon motor drive voltage fine adjustment
(Ribbon take-up side)
Ribbon motor drive voltage fine adjustment
(Ribbon supply side)
Ribbon motor drive voltage fine adjustment
(Ribbon take-up side)
Ribbon motor drive voltage fine adjustment
(Ribbon supply side)
RIBBON TORQUE RSV1 (B-EX6T1/T3 only)
Ribbon motor drive voltage fine adjustment
(Ribbon take-up side)
Ribbon motor drive voltage fine adjustment
(Ribbon supply side)
X-coordinate fine adjustment
Threshold fine adjustment for reflective sensor
Threshold fine adjustment for transmissive
sensor