58
[Counting condition] The number of times the print head moves up and down
with the solenoid for ribbon save is counted. (A set of up and down is counted
as one.)
The head up/down count is saved every 4 head up/down operations.
RIBBON
[Description] Ribbon motor drive time
[Range] 0 to 2000 hours
[Counting condition] Counted when the ribbon motor is driven while media feed
or printing. (Reverse feed is also counted.)
When the power is turned off, drive time of 10 seconds or less is rounded
down when backed up.
SOLENOID
[Description] Head-up solenoid drive time
[Range] 0 to 1000 hours
[Counting condition] Counted when the ribbon save operation is performed.
When the power is turned off, drive time of 10 seconds or less is rounded
down when backed up.
232C ERR
[Description] The number of times an RS-232C hardware error occurred
[Range] 0 to 255
[Counting condition] Counted when a parity error, overrun error or framing
error occurs.
SYSTEM ERR
[Description] The number of times a system error occurred
[Range] 0 to 15
[Counting condition] Counted when a system error occurs.
POWER FAIL
[Description] The number of times a momentary power interruption occurred
[Range] 0 to 15
[Counting condition] Counted when a momentary power interruption occurs.
<< ADJUST >>
Item
Description
Remarks
[PC]/[KEY]
FEED
Feed amount fine adjustment
-50.0mm to +50.0mm
CUT
Cut position (or strip position) fine adjustment
-50.0mm to +50.0mm
BACK
Reverse feed amount fine adjustment
-9.9mm to +9.9mm
TONE (T)
Print density fine adjustment
(Thermal transfer print mode)
B-EX6T1/T3: -20 to +20 step
B-EX4T1: -10 to +10 step
TONE (D)
Print density fine adjustment
(Direct thermal print mode)
B-EX6T1/T3: -20 to +20 step
B-EX4T1: -10 to +10 step
RIBBON TORQUE NORM
RBN (FW)
Ribbon motor drive voltage fine adjustment
(Ribbon take-up side)
-15 to +10 step
RBN (BK)
Ribbon motor drive voltage fine adjustment
(Ribbon supply side)
-15 to +10 step
RIBBON TORQUE LOW
RBN (FW)
Ribbon motor drive voltage fine adjustment
(Ribbon take-up side)
-15 to +10 step
RBN (BK)
Ribbon motor drive voltage fine adjustment
(Ribbon supply side)
-15 to +10 step
RIBBON TORQUE RSV1 (B-EX6T1/T3 only)
RBN (FW)
Ribbon motor drive voltage fine adjustment
(Ribbon take-up side)
-15 to +10 step
RBN (BK)
Ribbon motor drive voltage fine adjustment
(Ribbon supply side)
-15 to +10 step
X ADJ.
X-coordinate fine adjustment
-99.5mm to +99.5mm
THRESHOLD<R>
Threshold fine adjustment for reflective sensor
0.0V to 4.0V
THRESHOLD<T>
Threshold fine adjustment for transmissive
sensor
0.0V to 4.0V

Table of Contents

Other manuals for Toshiba B-EX6T Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba B-EX6T Series and is the answer not in the manual?

Toshiba B-EX6T Series Specifications

General IconGeneral
BrandToshiba
ModelB-EX6T Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals