ERROR CODE AND TROUBLESHOOTING
8 - 187
[CB30] Movable tray shift motor (M1) abnormality, Movable tray paper top detection error
MJ-1032
Movable tray shift motor (M1)
Stack top detection solenoid (SOL1)
Stack top detection sensor-1 (S1)
Stack top detection sensor-2 (S2
Movable tray lower limit sensor (S14)
A locking signal is detected after the specified time
*while the movable
tray is moving.
* A locking signal is not monitored from the start driving the motor until
the specified time has passed.
The stack top position of paper is not detected after the movable tray
shift motor (M1) is driven in the specified time when the movable tray is
moved up.
The lower limit position of the stack top of paper is not detected after
the movable tray shift motor (M1) has been driven in the specified time
during the initial movement of the movable tray.
The turning OFF of the movable tray lower limit sensor (S14) is not
detected when the movable tray is moved from a point where this
sensor is turned ON to one point where this sensor is turned OFF after
the movable tray shift motor (M1) has been driven in the specified time.
Probable cause Checking and measures
Movable tray shift motor (M1)
abnormality
Check if the electrical continuity of the coil is normal. If electricity is not
conducted, replace the motor
Movable tray lower limit sensor (S14)
abnormality
Measure the voltage on TP17 on the finisher control PC board (FIN).
Then check that the measured voltage is 1V or lower when not
shielded and within the range of 3.3V
5% when shielded. If the voltage
does not fall within the range mentioned, replace the sensor.
Faulty cables and connectors
Check if the electrical continuity among the connector terminals is
normal. If electricity is not conducted, replace the connectors. (Finisher
control PC board (FIN): CN4, CN10)
Finisher control PC board (FIN)
abnormality
If the error still occurs after replacing the motor, sensors and
connectors, exchange the finisher control PC board (FIN).
Stack top detection solenoid (SOL1)
abnormality
Check if the electrical continuity of the coil is normal. If electricity is not
conducted, replace the solenoid.
Stack top detection sensor-1 (S1)
abnormality
Measure the voltage on TP11 on the finisher control PC board (FIN).
Then check that the measured voltage is 1V or lower when not
shielded and within the range of 3.3V
5% when shielded. If the voltage
does not fall within the range mentioned, replace the sensor.
Stack top detection sensor-2 (S2)
abnormality
Measure the voltage on TP20 on the finisher control PC board (FIN).
Then check that the measured voltage is 1V or lower when not
shielded and within the range of 3.3V
5% when shielded. If the voltage
does not fall within the range mentioned, replace the sensor.
Faulty cables and connectors
Check if the electrical continuity between the connector terminals is
normal. If electricity is not conducted, replace the connector. (Finisher
control PC board (FIN): CN3)
Finisher control PC board (FIN)
abnormality
If the error still occurs after replacing the solenoid, sensors and
connector, exchange the finisher control PC board (FIN).