e-STUDIO477S/527S/477SL © 2013-2016 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
5 - 38
[EAF5] Lever path HP abnormality
[EAF6] Front alignment HP abnormality
Paper support motor • Motor check (M6)
• Connector check (P6-1)
• Harness check
Finisher control PC board • Board check
• Connector check (J6, J7)
• Harness check
Parts to be replaced Remark
Paper support home position
sensor
Paper support motor
Finisher control PC board
Classification Error content
Finisher related service call Lever path HP abnormality
Check item Measures
Lever path home position
sensor
• Sensor check (S15)
• Connector check (P7-4)
• Harness check
Lever path motor • Motor check (M10)
• Connector check (P18-1)
• Harness check
Finisher control PC board • Board check
• Connector check (J7, J18)
• Harness check
Parts to be replaced Remark
Lever path home position
sensor
Lever path motor
Finisher control PC board
Classification Error content
Finisher related service call Front alignment HP abnormality
Check item Measures
Front alignment plate home
position sensor
• Sensor check (S4)
• Connector check (P8-3)
• Harness check
Front alignment motor • Motor check (M4)
• Connector check (P6-12)
• Harness check
Finisher control PC board • Board check
• Connector check (J6, J8)
• Harness check
Check item Measures