4.4.2 Density adjustment
Adjusts the center density.
<Adjustment Mode (05)>
<Adjustment Mode (05)>
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in a code and press the [START] button.
(3) Key in an adjustment value (acceptable values: 0 to 255).
(To correct a value once keyed in, press the [CLEAR] button.)
(4) Press the [OK] or [INTERRUPT] button to store the value in memory.
The equipment goes back to the ready state.
(5) Let the equipment restart and perform the scanning.
(6) If the desired image quality has not been attained, repeat step (1) to (5).
Color
Mode
Original mode
Item to be
adjusted
Remarks
Text/
Photo
Text Photo
Custom
mode
Color 8339 8340 8341 8380 Manual
density center
value
The larger the value is, the
darker the image becomes.
Acceptable values: 0 to 255
(Default: 128)
Mode
Original mode
Gray
Scale
Item to be
adjusted
Remarks
Text/
Photo
Text Photo
Custom
mode
Black 7444 7445 7446 7475 7447 Manual
density center
value
The larger the value is, the
darker the image becomes.
Acceptable values: 0 to 255
(Default: 128)
7456 7457 7458 7478 7459 Automatic
density