4
© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO477S/527S/477SL
SETTING / ADJUSTMENT
4 - 19
4.4.8 RGB conversion method selection
The color space conversion method of image is decided at color-scanning.
<Adjustment Mode (05)>
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in the codes and press the [START] button.
(3) Key in the adjustment values. Acceptable values: 0 to 3. (To correct the value once keyed in,
press the [CLEAR] button.)
(4) Press the [OK] or [INTERRUPT] button to store the value in memory. The equipment goes
back to the ready state.
(5) Let the equipment restart and perform the scanning job.
(6) If the desired image has not been attained, repeat step (1) to (5).
4.4.9 Adjustment of saturation
The saturation of the scanned image is adjusted for color-scanning.
<Adjustment Mode (05)>
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in the codes and press the [START] button.
(3) Key in the adjustment values. Acceptable values: 0 to 255.
(To correct the value once keyed in, press the [CLEAR] button.)
(4) Press the [OK] or [INTERRUPT] button to store the value in the memory. The equipment goes
back to the ready state.
(5) Let the equipment restart and perform the scanning job.
(6) If the desired image has not been attained, repeat step (1) to (5).
Code Original mode Remarks
8319 Text/Photo 0: sRGB, 1: AppleRGB, 2: ROMMRGB, 3: AdobeRGB
(Default: 0)
8320 Text
8321 Photo
8372 Custom mode
Code Original mode Remarks
8324 Text/Photo The larger the value is, the brighter the image becomes.
The smaller the value is, the duller the image becomes.
Acceptable values: 0 to 255 (Default: 128)
8325 Text
8326 Photo
8373 Custom mode