e-STUDIO477S/527S
05/08
Mode
Element
Sub Element
Item
Subitem
Code
Sub-
Code
Details
Default
value
Acceptable
value
RAM
Contents
Proc
edure
ServiceUI
08
Destination setting
0: Japan 1: Asia 2: Australia 3: Hong Kong 4:
U.S.A./Canada 5: Germany 6: U.K. 7: Italy 8:
Belgium 9: Netherlands 10: Finland 11: Spain
12: Austria 13: Switzerland 14: Sweden 15:
Denmark 16: Norway 17: Portugal 18: France
19: Greece 20: Poland 21: Hungary 22: Czech
23: Turkey 24: South Africa 25: Taiwan 26:
Russia 27: Brazil
<Default value>
NAD: 4
MJD: 5
JPD: 0
Others: 1
Setting
mode
System
Option
FAX
9001
Refer to
contents
0~27
1
SYS
08
OEM identification code
destination
0: TOSHIBA
1: OKI
Setting
mode
System
General
9003
0
0~1
2
SYS
08
Line adjustment mode
0: For factory shipment
1: For line
Field: "0" must be selected
Setting
mode
System
General
9010
0
0~1
1
SYS
08
Language selection to be
displayed at power-ON
en_US: English
de_DE: German
fr_FR: French
es_ES: Spanish
it_IT: Italian
ja_JP: Japanese
en_GB: English (British)
zh_CN: Simplified Chinese
zh_TW: Traditional Chinese
ko_KR: Korean
<Default value>
JPD: Japanese
MJD: English (British)
Others: English
Setting
mode
System
General
9012
Refer to
contents
11
SYS
08
Externally installed counter
0: No external counter
1: Coin controller
5: Coin controller supporting ACS/mixed-size
* This code is a special code which has areas in
both SYS-SRAM and PU. The default value in
SYS-SRAM is applied to the PU area at
initialization.
Setting
mode
System
User interface
9016
0
0, 1, 5
1
SYS
08
Setting for counter installed
externally
Selects the job to count up for the external counter.
0: Not selected
1: Copier
4: Printer
5: Copier/Printer
* This code is a special code which has areas in
both SYS-SRAM and PU. The default value in
SYS-SRAM is applied to the PU area at
initialization.
Setting
mode
System
Counter
9017
1
0, 1, 4, 5
1
SYS
08
Size information
of
 
memory
Displays the sizes of the main memory and page
memory.
Enables to check if each memory is properly
recognized.
Setting
mode
System
General
Memory
9020
2
Yes
SYS
08
Initialization after software
version up
Perform this code when the software in this
equipment has been upgraded.
Setting
mode
System
Initialization
9030
3
Yes
SYS
52
Ver03
08 Setting Mode