[710F] Language Pack installation failure
[711D] License key returning failure
[711F] License key installation failure
[71A4] Cryptographic key consistency confirmation failure
Classification Error item
Maintenance error Language Pack installation failed.
Check item Measures
Setting Language Pack file may have a problem or may be corrupted.
Check the package file and then reattempt the installation.
Classification Error item
Maintenance error The one-time dongle license fails to be returned to USB
device.
Check item Measures
Setting Return the license to the USB device used for installing the
license.
Check that the USB device is correctly installed.
Notes:
The GP-1080 IPSec Enabler cannot return to the USB
device due to license problem.
The GP-1070 Overwrite Enabler cannot return to the
USB device in the high security (08-8911: 3).
Classification Error item
Maintenance error The one-time dongle license fails to be installed.
Check item Measures
Setting Check that the USB device is correctly installed.
Classification Error item
Maintenance error Cryptographic key consistency confirmation failed.
Check item Measures
Setting Start up the equipment in the following procedure:[3] + [C] +
[POWER] 5. Key Backup RestoreThen overwrite the