[F106_5] ADI-HDD error: Authentication data transmission error
[F106_6]/[F106_7]/[F106_8]/[F106_10] /[F106_UNDEF] ADI-HDD error: Error caused by reason
other than F106_0 to 5 errors
Classification Error item
Other service call ADI-HDD error: The transmission of authentication data fails.
Check item Measures
Setting Reinstall the system firmware.
Reinstall the system software.
• In case this error occurred after returning SRAM data for
SRAM cloning:
Copy the ADI-HDD encryption key from FROM to
SRAM.
1. Start the equipment in the 3C mode: [3] + [C] +
[POWER]
2. The authentication menu is displayed. Press [OK]. (Not
required in the default setting)
3. Select "5. Key Backup Restore" and then press the
[START] button.
4. Select "6. ADIKey FROM to SRAM" and then press the
[START] button.
5. After the restoring of the encryption key has completed,
"Operation Complete" is displayed.
6. After the operation has completed, shut down the
equipment by pressing the [POWER] button.
HDD If the error persists even after above step, replace the HDD.
If the equipment operation disabled after above step,
replace the HDD.
Classification Error item
Other service call
ADI-HDD error: Error caused by reason other than F106_0 to 5
errors
Check item Measures
Setting Perform [3]+[C]+[POWER]-> [3.Format HDD], and then
install the system software by performing
[4]+[9]+[POWER]-> [4.System Software(HD data)].
Notes:
The following items will be deleted by performing
[3]+[C]+[POWER]-> [3.Format HDD].
• Message Log
•Job Log
• Spool Data (Print, Email reception)
• Template
HDD If the error persists even after above step, replace the HDD.
If the equipment operation disabled after above step,