RF POWER SUPPLY and MATCHINGBOX
Figure 4-21 Arc shutoff operation configuration screen (P7)
Performs the arc cut operation when a reflected wave of "rated reflected wave
+ ASr2" is exceeded within the set time in ASDLY or after arc shutoff, even
when a reflected wave of the value set in ASr or greater occurs.
When this setting value is exceeded in the instant of output recovery
immediately after the arc shutoff operation, perform the arc shutoff operation
regardless of the AMASK or other setting.
Figure 4-22 Limit configuration screen (P8)
Excessive reflected wave level threshold setting.
Excessive VPP alarm level threshold setting.
Alarm when VPP voltage is detected that exceeds the setting value for the
rated VPP voltage.
An alarm when this set amount of time elapses in a state where there is a
reflected wave of the PrOL setting value or higher.
Sets the reflected wave alarm mask time after RF-ON.
Sets the output limit value for the rated Pf value for each program number.