5 SETTING OF FUNCTIONS
73
SETTING OF FUNCTIONS
Chapter
5
- Reading waveform data
-
Wave form hold point data read-out
(data No, a mark, a decimal point,5 figures of directions value)
Hold Mode Hold Section Rel.magnification
0: OFF 0: All 0: ×0.25
1: Sample 1: EXT 1: ×0.50
2: Peak 2: EXT+TM 2: ×0.75
3: Valley 3: LVL+TM 3: ×1.00
4: P-P 4: LVL 4: ×1.25
5: Average 5: ×1.50
6: Inf. Pnt 6: ×2.00
7: Rel. Max 7: ×3.00
8: Rel. Min 8: ×4.00
9: Rel. Dif
Graph Mode Level detection conditions Calibration Selection
0: Continued 0: Passed 0: Cal.0
1: Ext 1: Passed HI 1: Cal.1
2: Level 2: Passed LO 2: Cal.2
3: Ext+Level 3: Beyond 3: Cal.3
4: Below 4: EXT.
Set value correspondence table
Host
F372A
G
R
CR
Decimal Point and Five digits Data1
00 - 19
R
Data Section No.
G
±
00 - 19
Data Section No.
……
Delimiter
±±
……
Decimal Point and Five digits Data9 Decimal Point and Five digits Data10
Host
H
R
R
H
……
CR
Delimiter
10 0 00025
DATA000 - 199
F372A
One graph plotting screen
includes 200 pieces of data. In
reading waveform data, data can
be read by being divided into 20
sections (by 10 pieces).
Data Section No.
Y
DZ
X
Plotting Range
Data 0
Data 199
Section 00 Data 0 - Data 9
Section 01
Data10 - Data 19
Section 19
Data190 - Data 199