EasyManua.ls Logo

Vacon 100 flow - VACON 100 INDUSTRIAL - Technical Data

Vacon 100 flow
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.2 VACON
®
100 INDUSTRIAL - TECHNICAL DATA
Table 43: The technical data of the VACON
®
100 INDUSTRIAL AC drive
Technical item or function Technical data
Mains connection
Input voltage U
in
208-240 V, 380-500 V, 525-690 V,
-10%...+10%
Input frequency 50-60 Hz, -5...+10%
Connection to mains Once per minute or less frequently
Starting delay 8 s (MR8 to MR12)
Mains Mains types: TN, TT, and IT
Short circuit current: the maximum short circuit cur-
rent must be < Icc 65 kA.
Motor connection
Output voltage 0-U
in
Continuous output current I
L
: Ambient temperature max. +40 °C overload 1.1 x I
L
(1 min/10 min)
I
H
: Ambient temperature max. +40 °C overload 1.5 x I
H
(1 min/10 min)
I
H
in MR8-MR9: Ambient temperature max. +50 °C
I
H
in 690 V drives: Ambient temperature max. +40 °C
overload 1.5 x I
H
(1 min/10 min)
Output frequency 0-320 Hz (standard)
Frequency resolution 0.01 Hz
VACON · 110 TECHNICAL DATA, VACON® 100 INDUSTRIAL