EasyManuals Logo

Vacon 100 flow Installation Manual

Vacon 100 flow
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
3 RECEIVING THE DELIVERY
Before a VACON
®
AC drive is sent to the customer, the manufacturer makes many tests on
the drive to ensure its quality. When you receive the delivery, examine the packaging
carefully. After you remove the packaging, examine the drive for transport damages.
If the drive was damaged during the shipping, speak to the cargo insurance company or the
carrier.
To make sure that the contents of the delivery is correct and complete, compare the type
designation of the product to the type designation code. See Chapter 3.2 Type designation
code.
3.1 PACKAGE LABEL
To make sure that the delivery is correct, compare your order data to the data on the
package label. If the delivery does not agree with your order, speak to the vendor
immediately.
A B
H
G
F
E
D
C
I
Danfoss Industries Pte. Ltd.
MSIP-REM-V93-VC100
VAF
1000418030
V00001331708
70-AB3L07305W12B030BM26-00074393
Danfoss A/S, 6430 Nordborg, Denmark
3~AC,0-Uin, 0-320Hz
Uin:3~AC,380-500V, 50/60Hz
730A 40°C / 650A 50°C
724A 40°C / 642A 50°C
400kW:400V / 600HP:480V
IP00/Open Type
Made in Finland
POWER:
OUTPUT:
INPUT:
VACON0100-3L-0730-5+IP00
170120
16695624
FW0072V025
Marks:
Cust. Ord. No:
Application:
Firmware:
B.ID:
V00001331708
S/N:
70-AB3L07305W12B030BM26-00074393
Code:
Type:
AC DRIVE
Fig. 2: The package label of VACON
®
AC drives
A. The batch ID
B. The VACON
®
order number
C. The type designation code
D. The serial number
E. The mains voltage
F. The nominal output current
G. The IP class
H. The application code
I. The order number of the customer
VACON · 14 RECEIVING THE DELIVERY
3
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/

Table of Contents

Other manuals for Vacon 100 flow

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon 100 flow and is the answer not in the manual?

Vacon 100 flow Specifications

General IconGeneral
Protection classIP20
Communication interfaceRS-485
Operating temperature-10°C to +50°C
Storage temperature-40°C to +70°C
Ambient temperature-10°C to +40°C
Control methodSensorless vector control
Communication protocolsCANopen
ApprovalsCE, UL
I/O2 analog inputs
Protection featuresOvercurrent, overvoltage, undervoltage, overtemperature
Frequency range0 Hz to 400 Hz
Humidity5% to 95%, non-condensing
Voltage range208-240 V