EasyManua.ls Logo

VEMAG ROBOT HP7E - 6.6.3.7 Back suction; 6.6.3.8 LPG belt speed; 6.6.3.9 Portions per minute

VEMAG ROBOT HP7E
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ROBOT HP7E / HP10E / HP12E / HP15E / HP20E 6. Graphical control
6-29© VEMAG 2010
6.6.3.7 Back suction
Display: Back suction
Selection: On / Off
Unit: Gramme [g]
Resolution: 0.1 g
Setting range: 0 – 200 g (0 - 120 g for DP machines)
Application: When switched on, back suction prevents the product
running on once a portion has ended.
Enter back suction quantity. Entering "0" switches off the parameter.
Press Enter.
Machines which are not equipped with the standard lling horn holder
but have a larger machine outlet may not perform back suction for safety
reasons. In this case, back suction is blocked. The back suction quantity
may not exceed the specied weight dened in weight (does not apply to
“LPG” mode).
6.6.3.8 LPG belt speed
Display: LPG belt speed
Unit: Per cent [%]
Resolution: 1 %
Setting range: 0 – 100 %
Application: Speed of the dividing belts of the LPG
Enter belt speed.
Press Enter.
Belt speed can be limited by lling rate and number of links.
6.6.3.9 Portions per minute
Display: Portions per minute
Unit: Number
Resolution: 0.1
Setting range: 1.0 – speed limit
Application: Cutter / continuous cutter / continuous PPM
Enter the portions per minute.
Press Enter.

Table of Contents

Related product manuals