6.6.4.44 Maximum lling pressure (pressure monitoring on grinding system)
Display: Max. lling pressure
Unit: Bar [bar]
Resolution: 0.1 bar
Setting range: Off / 10 – 50 bar (depending on the machine)
Application: Separation grinder 982, separation attachment 801
• Enter max. lling pressure which, when reached, will cause the
machine to stop.
• Press Enter.
This function monitors pressure in separation grinder 982/ separation
attachment 801. Current pressure is displayed in bar. When the maximum
pressure entered is reached, the machine is stopped. Pressure can be
reduced by reducing speed.
The pressure is monitored even if these settings are deactivated. In this
case, the monitoring refers to the maximum value set in the machine
conguration settings.
Warning!
The machine stopping can be an indication that blades and hole plates
are blocked with sinew. In this case, clean the blade set.
6.6.4.45 Maximum temperature (temperature monitoring for the grinding system)
Display: Temperature
Unit: Degrees [°C] / Kilogram [kg]
Resolution: 0.1 °C / 1 kg
Setting range: Off / -19.9 °C – +31.0 °C / 1,0 kg - 99 kg
Application: Separation grinder 982, separation attachment 801
• Enter the max. temperature, at which to sound the alarm.
• Enter the min. temperature to dene a temperature range you wish to
monitor.
• Enter the lling volume still to be reached after the alarm is sounded
before the machine stops.
• Press Enter.
This function monitors temperature in separation grinder 982/ separation
attachment 801. Current temperature is displayed in degrees Celsius.
If the temperature is outside the dened range, a message is issued
and the relevant indicator comes on.