ROBOT HP7E / HP10E / HP12E / HP15E / HP20E6. Graphical control
6-36 © VEMAG 2010
Working with the length portioning machine
6.6.4.12 Product type
Display: Product type
Selection: Cooked sausage / Fresh sausage
Application: LPG
Enter product type
Press Enter.
6.6.4.13 Last portion
Display: Last portion
Unit: Per cent [%]
Resolution: 0.1 %
Setting range: 1 – 100 % / 0 = Off
Application: LPG
Enter value in per cent up to which the last portion is to be lled.
Press Enter.
6.6.4.14 Split casing tolerance
Display: Burst tolerance
Selection: Off/Value
Unit: Value
Resolution: 1
Setting range: 2 – 12
Application: LPG 208 with TM 203
Enter value up to which defective link points / split casings are to be
tolerated.
Press Enter.
The higher the value set, the less sensitively the machine reacts.
Example:
setting = 12, i.e. machine only stops after 12 faulty links (split casings).