ROBOT HP7E / HP10E / HP12E / HP15E / HP20E 6. Graphical control
6-41© VEMAG 2010
6.6.4.26 Permitted deviation
Display: Permitted deviation
Unit: Number
Resolution: 1
Setting range: 0 – max. number of sausages per stick
Application: Hanging
• Enter the number of sausages which may be missing on the smoke stick.
• Press Enter.
This parameter can only be used if the parameter "Sausages per stick"
is dened.
Here you enter the number of sausages which may be missing on the
number dened in "Sausages per stick".
Example:
sausages per stick = 20
permitted deviation = 3 (i.e. a smoke stick is considered complete,
even with 17 sausages)