T-1 Alarm Pro grammin g 2-303
Features and Operation
STARPLUS STSe - Programming & Operations Manual August 2005
Data Errors Alarm
Description
Data errors are illegal bit formations. If the Data Errors Alarm is enabled, an error message is
sent to the Attendant when the data error limit is reached.
Programming Steps
1. Press the DATA ERRORS flexible button (FLASH 47, Button #7). Button #7 and Button #11
LEDs are lit steady. The following message displays:
2. Enter a 0 or 1 on the dial pad to enable/disable this feature.
[0] = Disabled
[1] = Enabled
3. Press HOLD button to save entry. A confirmation tone sounds and the display updates.
4. Continue to program Data Error Alarm parameters using steps provided in this section for
Clearing the alarm, Minor alarm, Major alarm, Time Period, and Attendant display.
DEFAULT … Data Errors Alarm is enabled for all T-1 Trunks.
Clear Alarm
Description
The Clear Alarm option allows the alarm condition reported to the Attendant Display to be
cleared.
Programming Steps
1. Press the CLEAR ALARM flexible button (FLASH 47, Button #12). Button #12 LED is lit
steady. The following message displays:
2. Press the HOLD button to clear the alarm. A confirmation tone sounds.
DATA ERRORS 0-1
ENABLED
DATA ERRORS
CLEAR ALARM PRESS HOLD