2-304 T-1 Alarm Programming
Features and Operation
STARPLUS STSe - Programming & Operations Manual August 2005
Minor Alarm
Description
If the error counter for an Alarm Code reaches the number programmed as a Minor Alarm
within the time (in minutes) entered in the Time Period, the system reports a Minor Alarm
condition. The Minor Alarm threshold setting is variable from 00 to 99 minutes.
Programming Steps
1. Press the MINOR ALARM flexible button (FLASH 47, Button #13). Button #13 LED is lit
steady. The following message displays:
2. Enter a valid number (00-99) on the dial pad which represents the threshold limit.
3. Press the HOLD button to save the entry. A confirmation tone sounds and the display
updates.
DEFAULT … Minor Alarm threshold is set for 15 minutes.
Major Alarm
Description
If the error counter for an Alarm Code reaches the number programmed as a Major Alarm
within the time (in minutes) entered in the Time Period, the system reports a Major Alarm
condition. The Major Alarm threshold setting is variable from 00 to 99 minutes.
Programming Steps
1. Press the MAJOR ALARM flexible button (FLASH 47, Button #14). Button #14 LED is lit
steady. The following message displays:
2. Enter a valid number (00-99) on the dial pad which corresponds to the time period limit.
3. Press the HOLD button to save the entry. A confirmation tone sounds and the display
updates.
DEFAULT … Major Alarm threshold is set for 30 minutes and is variable from 00 to 99
minutes.
DATA ERRORS 00-99
MINOR ALARM 15
DATA ERRORS 00-99
MAJOR ALARM 30