Auxiliary dimmer unit (ADU)
If the existing installation comprises instruments that
are not of the EasyLink type, then an ADU can be
installed. This means non-EasyLink instrument can
also have the lighting intensity adjusted with the dim-
mer function.
ADU
Non-EasyLink-
equipment
SB, 0 V
R/BL, Fused supply
EasyLink-instrument
R/GR, out -
R, out +
Terminal block
Fuse box
Non-EasyLink-
equipment
Non-EasyLink-
instrument
Auxilary Supply
12 V/24 V
IMPORTANT! Connect supply via re-
lay for external accessories.
Auxilary Supply
12 V/24 V
SB = (solid) black
R = red
R/BL = red/blue
R/GR = red/gray
Fuse max 5A
R, Out +
R/GR, Out -
R/BL
SB
ADU
EVC instrument bus
In resp. Out
LEDs with dropping resistor (or lamps)
connected in parallel
The ADU can be fitted anywhere along the chain of
other EasyLink instruments. See the figure below.
The number of ADUs required depends on how many
filament lamps/LEDs there are in the circuit. One
ADU can supply 5 x 1.2 W (12 V/24 V) filament lamps
or 30 x LEDs, 15 mA (12 V/24 V).
When attaching to the auxilary + supply, an extra
fuse of max 5 A must be used. See positioning in fig-
ure below
EasyLink
connection
EasyLink
connection to
tachometer
EVC System
Tachometer
61
EVC-C Installation procedure, helm