Accessories E 3000
5.17 Connecting One HX 200 Heat Exchanger
Requirements
Machine stopped
One HX 200 Heat Exchanger
Connect the
HX hoses
1. Position the Heat Exchangers (a) within the space to be heated.
2. Connect Heat Exchanger (a) to left accessory supply (LS).
3. Connect Heat Exchanger (a) to return plumbing rack (LR).
Complete the
installation
1. Insulate the supply and return hoses.
2. Connect the Heat Exchangers to the appropriate electrical source.
3. Connect the DPP power cord to the APP.
4. Open cross-connect valve #5.
5. Close valve #4 and valve #6.
Run the
machine
NOTICE: Only turn on the pumps when the Heat Exchangers are connected.
Turning on the pumps when the Heat Exchangers are not connected will cause
excess system pressure which may damage the pumps.
1. Start the E 3000 and operate it with the temperature controller set to 180°F
(80°C).
2. Turn on the Heat Exchangers and adjust the thermostats as desired.
Result
The Heat Exchangers have now been connected and are operating.
wc_gr008585
a
LR
LS
HX 200