Page #52 background imageLoading...
Page #52 background image
wc_tx001951gb.fm
52
Operation E 3000
4.14 Positioning the Machine
CO Alarms
Because this machine produces carbon monoxide (CO), Wacker Neuson
recommends that CO alarms be installed in all structures in close proximity to the
machine. CO alarms provide an extra measure of protection against this poison
that you cannot see or smell.
Install battery-operated CO alarms or plug-in CO alarms with battery backup,
according to the manufacturers instructions. CO alarms should be certified to the
requirements of the latest safety standards (UL 2034, IAS 6-96, or CSA 6.19.01).
Test the CO alarm batteries monthly.
Requirements
Position the machine:
so that burner exhaust will not enter nearby structures.
so that the machine does not block traffic.
so that the machine is not close to any combustible material or flammable vapor.
so that all of the machine’s access doors/panels may be accessed.
so that HTF hoses do not pose tripping hazards, and so the HTF hoses cannot
be damaged by machines or other equipment on the job site.
This procedure continues on the next page.
DANGER
Asphyxiation hazard.
Exhaust gas from the burner contains carbon monoxide, a deadly poison you
cannot see or smell. Exposure to carbon monoxide can kill you in minutes.
f Position the machine so that burner exhaust will not enter any nearby
structures.
WARNING
Fire hazard. Do not move the machine while it is running.
f Shut down the machine before moving or repositioning it.
WARNING
Fire hazard. Machines positioned on a hill or an incline may slide, break away or
roll over.
f Do not position the machine on a hill or an incline.
WARNING
Explosion and fire hazard. Risk of severe injury or death.
f Do not operate the machine near flammable vapors, fuels, or combustibles.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson E3000 and is the answer not in the manual?

Wacker Neuson E3000 Specifications

General IconGeneral
Electrical Requirements230 V, 50 Hz
Voltage230 V
Operating Voltage230 V
Heat Capacity3000 W
Fuel Consumption0.3 l/h
Tank Capacity12 l
Fuel Tank Capacity12 l
Heating Capacity3000 W
Fuel Consumption (l/h)0.3 l/h
Tank Capacity (l)12 l
Power Consumption3 kW