wc_tx001802gb.fm
112
Burner Setup—Oil E 3000
6.3 Setting/Checking the Electrodes
Requirements
Power supplies disconnected
Ruler/measuring device
Procedure
Follow the procedure below to check the electrodes.
1. Disconnect the power supplies.
2. Remove the copper fuel line (a) between the fuel pump and the burner housing.
3. Remove the spline nut (b) that is seated against the escutcheon plate.
4. Remove screws (c) and open igniter cover.
5. Disconnect the wiring (e) to the nozzle/electrode assembly.
.
6. Maneuver the nozzle/electrode assembly (d) up and out of the burner.
This procedure continues on the next page.
wc_gr008581
c
wc_gr008596
e
wc_gr008597
d