wc_tx001803gb.fm
142
Maintenance E 3000
8.6 Cleaning the HTF Strainer
Requirements
Machine shut down
Source of clean, warm water
Removal
Perform the procedure below to clean the HTF strainer.
Note: In the interests of environmental protection, place a plastic sheet and a
container under the machine to collect any liquid which drains off. Dispose of this
liquid in accordance with local environmental protection laws.
1. Loosen, but do not remove, the top screw (a).
Note: There is a second screw (b) under the canister (c). Hold this screw while
loosening the screw (a).
2. Tap on screw (a) with a hammer to release the gasket seal.
3. Remove the canister (c) by removing screw (a)—support the canister while
doing so.
4. Dispose of the HTF that remains in the canister.
5. Remove the gasket (d) from the canister. Replace it if it is damaged.
6. Remove the strainer basket (e) from the canister.
7. Rinse the strainer basket and the canister with clean, warm water.
This procedure continues on the next page.