Maintenance E 3000
8.5 Filling the HTF Reservoir
Requirements
Genuine Wacker Neuson Heat Transfer Fluid, or
Dowfrost HD 50 Heat Transfer Fluid
Machine is on a level surface
NOTICE: Use only factory-recommended Heat Transfer Fluid (HTF). Failure to
comply may damage the machine.
Background
The procedure for routine filling of the HTF reservoir differs slightly from that when
a low level fault is encountered. If your machine has experienced a low level fault,
see topic “Resetting a Low HTF Fault” .
Procedure
Follow the procedure below to fill the HTF reservoir.
1. Move the burner switch to the OFF position.
2. Move both pump switches to the OFF position.
3. Clean the fill hose.
4. Power up the machine.
5. Remove the locking pin, then open valve #3 and close valve #2 simultaneously.
6. Place the open end of the fill hose (a) into a container full of HTF.
This procedure continues on the next page.