E 3000 Operation
4.18 Applying Power to the Machine
Requirements
Pre-starting checks have been completed
Power connected to the machine
Procedure
Follow the procedure below to apply power to the machine.
1. Move both circuit breaker switches (a) to the ON position.
2. Check that the indicator lights of both GFCIs (b) are off. Press the “RESET”
button of the GFCI if its indicator light is ON.
3. Check that the low-level-fault indicator light (c) is OFF. If this light is ON, add
Heat Transfer Fluid (HTF) to the reservoir. See topic Filling the HTF Reservoir.
4. Check that the displays of the temperature controller (d) illuminate. If the
displays of the temperature controller do not illuminate, there is a problem with
the GFCI 1 or with the wiring to the temperature controller. Disconnect the main
power supply and rectify the problem before continuing.
Result
The machine is ready for operation.
wc_gr008607
1
2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson E3000 and is the answer not in the manual?

Wacker Neuson E3000 Specifications

General IconGeneral
Electrical Requirements230 V, 50 Hz
Voltage230 V
Operating Voltage230 V
Heat Capacity3000 W
Fuel Consumption0.3 l/h
Tank Capacity12 l
Fuel Tank Capacity12 l
Heating Capacity3000 W
Fuel Consumption (l/h)0.3 l/h
Tank Capacity (l)12 l
Power Consumption3 kW