E 3000 Burner Setup—Gas
Continued from the previous page.
9. Conduct a smoke spot test. Follow the smoke spot tester manufacturer’s
instructions and the general guidelines below.
Use the access hole in the exhaust outlet.
Take several samples as the heater warms.
Take the final sample just before the heater reaches 71°C (160°F).
10.Analyze the combustion. Follow the combustion analyzer manufacturers
instructions and the general guidelines below.
Use the access hole in the exhaust outlet.
Take several samples as the heater warms.
Take the final sample just before the heater reaches 71°C (160°F).
11.Re-adjust the air setting(s) if necessary until the smoke spot test and
combustion analysis are within the following parameters:
O
2
content: 4–6%
Smoke spot: 1 or less
Result
The burner has now been set up.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson E3000 and is the answer not in the manual?

Wacker Neuson E3000 Specifications

General IconGeneral
Electrical Requirements230 V, 50 Hz
Voltage230 V
Operating Voltage230 V
Heat Capacity3000 W
Fuel Consumption0.3 l/h
Tank Capacity12 l
Fuel Tank Capacity12 l
Heating Capacity3000 W
Fuel Consumption (l/h)0.3 l/h
Tank Capacity (l)12 l
Power Consumption3 kW

Related product manuals