5.6 Installation of the safety shield retaining profile
1.
Operation of retention profile safety shield
1. Position the safety shield retaining profile (1) on
the round groove of the wall gap sealing profile
(2).
2. The safety shield retaining profile (1) can be tilted
downwards by the slewing ring.
Note:
Align the retaining profile for the safety shield so that
it is flush outside the cutting edge of the wall gap
sealing profile.
Note:
If the weinor PergoTex II is equipped with a third
side channel in the centre, the retention profile safety
shield (1) is delivered in two sections. The surge
point is sealed from above with the "retention profile
safety shield cover" (3). To do this, the sealing band
(4) is first adhered to the bottom side of the "retention
profile safety shield cover" (3). Then bolted with
drilling screws 3.9x13 Torx (5).
2.
Installation of suggestion: Installation of the
upper part top section of the "wall gap sealing
profile"
According to the structural conditions and size of
construction, the „upper part top section of the wall
gap sealing profile" can already be mounted at this
point.
See Chapter 5.18 Installation of the "upper part
top section of the wall gap sealing profile".
5.7 Sealing beaded profile with gutter
In case of a low roof pitch (- 2°), rainwater could flow through the "beaded profile with gutter" to
the back in the direction of the wall connection and ingress the interior area of the weinor
PergoTex II from there.
The "beaded profile with gutter" should be sealed
on site with an appropriate jointing compound to
ensure that rainwater cannot flow to the back
(Detail A).
Note:
If leads are routed through the "beaded profile with gutter",
they will also be sealed.
Round groove on wall
gap sealing profile
A
Left side channel with "beaded profile with
gutter" sealed to the back in the direction
of the wall connection. As an example, a
lead (with rubber seal), is pictured that is
also sealed.
Jointing compound
Example: lead (with rubber seal)
Side channel
Beaded profile with gutter

Table of Contents

Other manuals for weinor PergoTex II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the weinor PergoTex II and is the answer not in the manual?

weinor PergoTex II Specifications

General IconGeneral
Brandweinor
ModelPergoTex II
CategoryAccessories
LanguageEnglish

Related product manuals