2.8 Electrical connection
The weinor PergoTex II may only be connected to an electricity supply if the specifications
provided on the tag attached to the weinor PergoTex II and/or the specifications provided in the
supplied instructions for assembly tally with the power source. At the very least, the tag and/or
specifications must specify the voltage, frequency and output values.
The installation instructions accompanying the supplied electrical components must be
observed. A permanent electrical connection may only be made to power grids fitted with an all-
pole cutting of plate cylinder with a minimum 3 mm wide contact gap.
2.9 Intended use
The weinor PergoTex II is a sunscreen and rain protection construction and may only be used
for sun and rain protection. Failure to use the product as intended may result in severe danger.
Alterations such as attaching items, or conversions not envisaged by weinor may only be carried
out with weinor's written consent.
Additional loads on the weinor PergoTex II caused by hanging articles from it or by anchoring
ropes may result in damage or cause the weinor PergoTex II to fall and are therefore not
2.10 Unsupervised operation
When working in the range of movement of the weinor PergoTex II, the automatic controls must
be switched off. There is a danger of trapping or the awning falling down.
Measures must also be taken to ensure that the weinor PergoTex II cannot be operated
unintentionally. These include cutting off the power source, e.g. by disconnecting the fuses or
removing the connector coupling from the drive.
If the weinor PergoTex II is operated by several users, a steering priority locking device must be
installed (controlled interruption of the power supply from outside), making it impossible to open
or retract the weinor PergoTex II at all.
2.11 Crushing and cutting zones
If the weinor PergoTex II is installed at a height of less than 2.5 metres above areas accessed by
people, the weinor PergoTex II may only be operated using a key switch with all moving parts in
sight. Electrical controls, radio controls with latch switches, catchers etc. are not permissible
here.
The key switch must be fitted in the line of sight of the drop profile, but far enough removed from
the moving parts, at a height of 1.5 metres (national regulations relating to disabled people must