Alarm List
Alarm Number (4000 to 4999)
Alarm List-812
9 Zero or a negative value is set
in the maximum diameter
parameter (S1CxG064) for the
Form Cutting motion.
Setting error (1)Check the following settings.
∙ The setting of the maximum diameter parameter (S1CxG063) for the
Form Cutting motion.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
10 Although "PLACEMENT" or
"AUTO" is set for the start
point designation on the
FORM CUT SETTING
window, the FORMAPR
instruction was not executed.
Setting error (1)Check the following settings.
∙ Execute the FORMAPR instruction.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
11 The Cut file setting of the
FORMAPR instruction is
different from that of the
FORMCUT instruction.
Setting error (1)Check the following settings.
∙ The Cut file settings of FORMAPR and FORMCUT instructions must
be same.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
12 A FORMAPR instruction was
used for the conventional
FORMCUT instruction.
Setting error (1)Check the following settings.
∙ The FORMAPR instruction cannot be used for the conventional
FORMCUT instruction.
∙ Validate the new FORMCUT instruction.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy