Alarm List
Alarm Number (4000 to 4999)
Alarm List-824
16 Memoplay debug error
C_BANK RT_BANK.func_ctrl
(continue)
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
17 Memoplay debug error MOVL,
MOVC (continue)
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
18 Memoplay debug error Same
point, moving amount is zero
(continue)
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
19 Memoplay debug error
Dividing number error
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4611 OVER OPTON INST
EXECUTION LIMIT
Setting error (1)Check the following settings.
Check the settings for the OPTON instruction. OPTON instruction can
use only the function to five simultaneously.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4612 TSYNC ERROR Sub code: the number of
synchronizations of the first
executed TSYNC
Setting error (1)Check the following settings.
Check the settings for the number of synchronizations of the TSYNC
instruction.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4613 SERVO SEALER GUN
CONTROL ERROR
1 The function designation
parameter is not set.
Setting error (1)Check the following settings.
Check the settings for the function designation parameter.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy