Alarm List
Alarm Number (4000 to 4999)
Alarm List-842
65535 An attempt was made to
change the value of the
register currently used by
TMR/CNT.
Setting error (1)Check the following settings.
∙ Correct the setting of tag that specifies register number of SETREG
instruction.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4655 WRONG EXECUTION
OF GETREG INST
65535 An attempt was made to
acquire the value of the
register not existing.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4656 WRONG EXECUTION
OF SETPRM INST
1 An attempt was made to
change a parameter other
than the cube-related
parameter.
Setting error (1)Check the following settings.
∙ The SETPRM instruction cannot change the parameter values other
than the parameter related to the cube. Correct the setting of tag that
specifies parameter number of SETPRM instruction.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2 The SETPRM instruction was
executed while another
system was in execution.
Setting error (1)Check the following settings.
∙ The SETPRM instruction cannot execute while another system is
operating. Correct the job.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4657 WVADJ ERROR 1 The correction amplitude
value did not fall in the limit
range.
Setting error (1)Check the following settings.
∙ Correct the settings for "groove width correction limit value" specified
for S2C1259 and 1260.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4658 OVER SPEED LIMIT 1 The taught speed was going
to exceed the limit during the
multi arm simultaneous
operation.
Setting error (1)Check the following settings.
∙ Reduce the teaching speed of the step where the alarm occurred to
the speed limit or less.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy