Alarm List
Alarm Number (1000 to 1999)
Alarm List-219
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
25 The SRDY signal did not turn
ON after data were read.
(EEPROM reading error)
EAXA21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the EAXA21 board. Save the
CMOS.BIN before replace the board to be safe.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
26 The written data were rejected
at verification. (EEPROM
verify error)
EAXA21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the EAXA21 board. Save the
CMOS.BIN before replace the board to be safe.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
1020 MotoPlus application
load error
1 Num of the Application files on
the YCP21 CF is over the
limit.
Setting error Delete unnecessary application files "*.out" by MotoPlus menu in the
maintenance mode in order not to exceed the file number limitation.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2 Insufficient memory space.
At the loading time, remaining
CPU memory is less than
2Mbyte (Stipulated memory
size for MotoPlus) .
Setting error Under current system configuration and option function combination,
there is not enough memory to run MotoPlus application. If the alarm
occurs again, save the CMOS.BIN in maintenance mode, and then
contact your Yaskawa representative about occurrence status
(operating procedure).
It may be necessary to replace the YCP21 with the one with larger
memory.
3 MotoPlus application folder "/
Application"cannot be found.
Setting error (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then remove the CF from the failure YCP21 board to insert
it into the new YCP21 board.
Alarm
Number
Alarm Name Sub
Code
Meaning Cause Remedy